Part Number Hot Search : 
0515S 2228M E005214 28128 107M0 88810 PEMH1 D16801
Product Description
Full Text Search
 

To Download F1710AA03 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  curtis industries a division of powers holdings, inc. www.curtisind.com speci cations subject to change. dimensions are shown for reference purposes only. 22 single phase filters nominal current rating part number termination line/load minimum insertion loss - db (50 ohm circuit) mode .15 .50 1.0 5.0 10 30 3a f1700aa03 f1700bb03 f1700ca03 qc/qc wire/wire iec/qc common differential 20 25 35 60 43 65 52 65 55 50 50 50 F1710AA03 qc/qc common differential 20 25 34 60 40 65 45 65 45 50 40 50 f1720aa03 qc/qc common differential 20 35 32 60 35 65 35 60 35 55 40 40 f1740aa03 qc/qc common differential 20 35 30 60 35 65 35 60 35 55 40 40 6a f1700aa06 f1700bb06 f1700ca06 qc/qc wire/wire iec/qc common differential 10 15 22 50 30 65 46 60 50 60 45 60 10a f1700aa10 f1700bb10 f1700ca10 qc/qc wire/wire iec/qc common differential 10 20 22 45 30 60 46 65 50 60 45 55 20a f1700aa20 qc/qc screw/screw common differential 10 15 22 45 30 60 42 65 47 60 40 55 f1700dd20 f1720dd20 screw/screw common differential 10 15 22 45 30 60 42 65 47 60 52 55 30a f1700dd30 screw/screw common differential 7 15 15 45 20 60 34 65 42 60 40 55 f1799dd30 screw/screw common differential 10 15 45 65 55 65 60 65 60 60 50 55 f1700/f1799 rfi filters features: ? general purpose ? designed for applications with higher differential mode noise ? higher line-to-line capacitance for protection from pulsed, intermittent or continuous rfi ? a cost-effective replacement for independent coil design in many smps applications ? available with integral iec connector f1700 simpli ed schematic f1799 simpli ed schematic speci cations : rated voltage: 250vac maximum - 50/60 hz rated current: 115vac 250vac 3a 2.5a 6a 4a 10a 6a 20a 10a 30a 15a current overload: 6x for 8 seconds hi-pot test (1 min): line to ground 1500vac line to line 1768vdc insulation resistance: 9 x 10 9 at 100vdc ambient temperature: 40c max. at rated current humidity range: 0% to 95% r.h. termination: a: qc ? quick connect c: iec receptacle b: wire d: screw maximum leakage current: each line to ground f1700 f1710 f1720 f1740 f1799 115vac, 60hz: 0.40ma .15ma .002ma .060ma 0.25ma 250vac, 50hz: 0.75ma .25ma .005ma .120ma 0.45ma agency approvals: line l g n load l n note: other combinations of terminals may be speci ed on special order. high performance except 30amp line l g n load l n
curtis industries a division of powers holdings, inc. 1-800-657-0853 dimensions are in inches and millimeters unless otherwise speci ed. values in parentheses are metric equivalents. 23 single phase filters amps a b c d e 3a 2.750 (69,8) 1.750 (44,4) 1.125 (28,5) 2.375 (60,3) 2.000 (50,8) 6a 3.312 (84,1) 2.000 (50,8) 1.125 (28,5) 2.940 (74,7) 2.500 (63,5) 10a 3.312 (84,1) 2.000 (50,8) 1.500 (38,1) 2.940 (74,7) 2.500 (63,5) amps a b c d e 3a 2.000 (50,8) 2.000 (50,8) 1.500 (38,1) .550 (14,0) .565 (14,3) 6a 2.500 (63,5) 2.000 (50,8) 1.500 (38,1) .550 (14,0) .565 (14,3) 10a 2.500 (63,5) 2.000 (50,8) 1.500 (38,1) .550 (14,0) .565 (14,3) amps a b c d e f 3a 2.750 (69,8) 1.750 (44,4) 1.125 (28,5) 2.375 (60,3) 2.000 (50,8) .550 (14,0) 6a 3.312 (84,1) 2.000 (50,8) 1.125 (28,5) 2.940 (74,7) 2.500 (63,5) .550 (14,0) 10a 3.312 (84,1) 2.000 (50,8) 1.500 (38,2) 2.940 (74,7) 2.500 (63,5) .550 (14,0) 20a see 1700dd20 for case dimensions f1700aa, 1710, 1720, 1740 (3, 6 and 10amp) dimensions f1700bb (3, 6 and 10amp) dimensions f1700ca (3, 6 and 10amp) dimensions f1700dd20 (20amp) dimensions no. 18 gauge wire a d b e c 4.00 min. (101,6) .250 .062 (6,35) type. .188 dia. (4.77) 2 holes l i n e l o a d high performance f1700dd30 (30amp) dimensions f1799dd (30amp) dimensions terminals no. 8-32 (5) (4) .250 x .156 (6,35) (3,95) 1.520 (38,6) 5.075 (128,9) 2.000 (50,8) 3.312 (84,1) 4.140 (105,2) 3.750 (95,2) l i n e l o a d a d e f f c .250 qc (6,4) l i n e l o a d b .625 (15,87) 2.000 (50,8) .625 (15,87) 1.500 (38,1) 2.940 (74,7) 3.312 (84,1) 2.500 (63,5) (5) no. 8-32 studs .188 dia. (4.77) 2 holes l i n e l o a d also available with .250? quick connect terminals a d c e b (2) no. 6-32 unc2b l i n e l o a d refer to page 40 for standard mounting cutouts #8-32 screw terminal 50.8 (2.00) slotted hole, 6.4(.25)x4.0(.16) 3.96 (110,6) 3.5 (88,90) 5.95 (151,1) 3.12 (79,2) 2.18 (55,4)
curtis industries a division of powers holdings, inc. www.curtisind.com speci cations subject to change. dimensions are shown for reference purposes only. 40 single phase filters standard mounting cutouts f1200ca, f1300ca, f1400ca, f1500ca, f1600ca, f1700ca f1500fa, f1600fa, 1.145 (29,08) 1.417 (36,0) 1.275 (32,39) ? .09 r (2,29) .638 (16,21) .140 dia. (3,55) 2 holes 1.20 (30.5) .90 (22,9) 1.575 (40,0) .187 (4,75) .450 (11,43) .234 (5,94) .140 dia. (3,55) 2 holes f1300cp, f1600cp .062 hole dia. (1,57) 5 holes 1.500 (38,1) .600 (15,2) .700 (17,8) 1.400 (35,6) n l f5500/5600/5700 series .140 dia. (3,55) 2 holes .234 r. (5,94) (typ.) 1.575 (40,01) 1.20 (30,48) .90 (22,8) ? for mounting from back side series pe = power entry pm = medical power entry load termination a = quick connects b = wire leads d = screw terminals (20 & 30 amp only) p = printed circuit pins s = solder tab line termination a = quick connects b = wire leads c = iec connector d = screw terminals (20 & 30 amp only) f = fused iec p = printed circuit pins w = dual fused iec j = switched iec how to order the curtis part numbering system is made up of four elements. each element denotes a speci c requirement (mechanical or electrical) which, when properly sequenced, fully identi es the required catalog lter. as shown, the rst ve alpha/numeric characters denote the series type; the sixth character (alpha) denotes the type of line termination; the seventh character (alpha) denotes the type of load termination; the last two characters (numeric) denote the current rating. compose your part number as follows: select the series required, add two alpha character for the line and load termination, followed by two numeric characters for the required current rating. for example, f1100ab06 completely identi es an f1100 series lter with quick connects on line side and wire leads on load side, with a 6-amp rating. f1100 x x x current rating 01 = 1 amp 03 = 3 amps 06 = 6 amps 10 = 10 amps 15 = 15 amps 20 = 20 amps 30 = 30 amps


▲Up To Search▲   

 
Price & Availability of F1710AA03

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X